editorinchief@ijrtmr.com +91 9840521421 Scholarly Open Access, Peer-reviewed, Refereed Journal e-ISSN 2583-0368 Since 2021
  1. Home
  2. Archives
  3. 2025
  4. Vol. 5 Issue 5
  5. Article
Original Article

Influence of structure design parameters of chamber and buffer on thickness uniformity of iron oxide CVD thin film

  • Paper ID 223
  • Volume 5, Issue 5
  • Pages 122-129
  • Published Online: September-October 2025
  • 5 Views
Open Access Peer Reviewed Crossref DOI

Authors

  • Yong-Hyon Kim1
  • Yong-Ju Han2
  • Hak Bong Kim3

1 2 3 Student member, IEEE, Semiconductor Institute, Kim Chaek University of Technology, Yonggwang Street, Pyongyang, Democratic People’s Republic of Korea.

Article Information

Published Online
September-October 2025
Pages
122-129
Article Type
Original Article
Check for updates
check update

Abstract

View PDF

The iron oxide CVD thin film exhibits the various beautiful colors with the brilliance, and the technology effectively could be applied for varied color of an artificial gem.The iron oxide CVD thin film is used for the manufacture of the iron oxide photo plate called as a semi transparent mask. This paper aimed to progress the structure design of the buffer to enhance the thickness uniformity of iron oxide CVD thin film by means of a new numerical simulation method (Computational Fluid Dynamics numerical simulation) within the chamber. A new numerical analysis was carried out using “ANSYSFLUENT” program. The simulations were developed for a circular cone chamber and a circular cone buffer. There exists a good relationship between the thickness uniformity of iron oxide Chemical Vapor Deposition (CVD) thin film and the structure design parameters of chamber and buffer. This work discussed that the thickness uniformity of iron oxide CVD thin film is affected by the structure design parameters of circular cone chamber and a circular cone buffer and the reasonable structure design parameters of chamber and buffer were suggested. The comparison between the numerical analysis results and the experimental data was performed and a good agreement was found. The maximum deviation between them is less than 8%.