editorinchief@ijrtmr.com +91 9840521421 Scholarly Open Access, Peer-reviewed, Refereed Journal e-ISSN 2583-0368 Since 2021
  1. Home
  2. Archives
  3. 2026
  4. Vol. 6 Issue 2
  5. Article
Original Article

Design of a Constant Current Source for Reliable GSR Measurement Using IC LM317

  • Paper ID 341
  • Volume 6, Issue 2
  • Pages 454-457
  • Published Online: March-April 2026
  • 45 Views
Open Access Peer Reviewed Crossref DOI

Authors

  • Rajarshi Das1
  • Mainakh Chakroborty2
  • Jeet Sen3
  • Aritra Ghosh4
  • Tarak Das5

1 2 3 4 Student, Department of Biomedical Engineering, Netaji Subhash Engineering College, Kolkata, West Bengal, India. 5 Assistant Professor, Department of Biomedical Engineering, Netaji Subhash Engineering College, Kolkata, West Bengal, India.

Article Information

Published Online
March-April 2026
Pages
454-457
Article Type
Original Article
Check for updates
check update

Abstract

View PDF

Galvanic Skin Response (GSR) is a widely used physiological parameter that reflects variations in skin conductance arising from sweat gland activity. Since these glands are under the control of the sympathetic nervous system, changes in GSR provide a reliable indication of emotional arousal, stress, and other autonomic reactions. The measurement is typically made in regions where the density of sweat glands is high, allowing small fluctuations in sympathetic activity to produce detectable changes in voltage output due to change in skin resistance. To obtain dependable readings from such subtle variations, a stable and well- defined excitation source is essential. For this purpose, GSR systems commonly employ a constant current source. By delivering a small, steady current through the skin, the circuit ensures that any change in voltage across the electrodes truly represents a physiological change rather than a variation in the measuring device. This approach improves linearity, reduces the influence of electrode polarization, and enhances the overall accuracy of the measurement. For its sensitivity and simplicity, the GSR technique has become an important tool in psychological studies, biofeedback training, and clinical monitoring of autonomic function.

APC from ₹1200 + 18% GST

Peer-reviewed open access₹1200 Indian (₹1400 with DOI)$80 USD internationalpaid after acceptance Peer-reviewed open access₹1200 Indian$80 USD international ₹1200 Indian · $80 intl

  • CrossRef DOI
  • ISSN 2583-0368
  • Open Access
  • Peer Reviewed
  • Plagiarism Checked
  • Google Scholar
Submit Paper